Construction Process:
1. Waterproof treatment: The first floor need already finished waterproof treatment
2. Solidground: according to solidground condition to polish, mending, clear dust etc
3. static free primer painting: adopt strong adhesion static-free epoxy primer to painting 1 layer, enhance the adhesion of surface.
4. Laying copper foil: electric conduction copper foil laying like crosses, exclude the accumulate electrostatic, make grounding treatment.
5.Sealed copper foil: Use non-solvent floating coat to sealed the copper foil
6. Anti-static painting: according to actual demand to painting 1 or 2 layers.
7. Anti-static finish coat: painting 2 times, surface average coefficient of resistance 105 -109 Ω,after finished the whole surface shining and cleanly, color evenly, no bubbling.
8.Finished construction: only allow people step on it after 24h, heavy press after 72h.
9.Construction way: roller, brush, spraying
2. Solidground: according to solidground condition to polish, mending, clear dust etc
3. static free primer painting: adopt strong adhesion static-free epoxy primer to painting 1 layer, enhance the adhesion of surface.
4. Laying copper foil: electric conduction copper foil laying like crosses, exclude the accumulate electrostatic, make grounding treatment.
5.Sealed copper foil: Use non-solvent floating coat to sealed the copper foil
6. Anti-static painting: according to actual demand to painting 1 or 2 layers.
7. Anti-static finish coat: painting 2 times, surface average coefficient of resistance 105 -109 Ω,after finished the whole surface shining and cleanly, color evenly, no bubbling.
8.Finished construction: only allow people step on it after 24h, heavy press after 72h.
9.Construction way: roller, brush, spraying
Item NO. | Name | Description | Features | Application |
HL-K80 | Anti-static self levelling epoxy floor paint | HL-K80 made of solvent epoxy which add conductive material, work with curing agent in normal temperature condition to form a anti-static epoxy floor coat. Thickness: 1.5-5mm Usage time: Over 5-10 years | 1.Eliminate electrostatic and anti-static or electromagnetic wave, to avoid static spark and electromagnetic interference | Electronics and computer production and packing area. Telecommunication/electronic/computer control center Ammunition depot, powder magazine etc. |
Hualong Headquarter